Evocare Home Page
Return to home page


Search Alphabetical Product List

Vital Signs Monitor

Highly developed technology resulting in reliable measurement results and time efficiency.



mouseover for larger image


RVS-100 vital signs monitor

RVS-100 vital signs monitor

RVS-100 vital signs monitor, back


Riester RVS-100 Vital Signs Monitor

Advanced vital signs monitor for pulse oximetry, blood pressure and temperature measurements.

Riester’s RVS-100 is an advanced vital signs monitor which offers pulse oximetry, blood pressure and temperature measurements. The device has ‘Monitor’, ‘Spot-Check’ and ‘Triage’ profile options and a high performance touchscreen.

The RVS-100 can communicate through a wired or wireless connection to the hospital’s EMR, according to the HL7 standard.


  • 3 measurement modes (Monitor, Spot-check, Triage)
  • High-sensitivity 8" TFT colour touch screen with self-explanatory user interface and integrated help-function
  • Displays SYS, DIA, MAP, Pulse, Temp, Plethysmogram
  • Clinical grade NIBP* including averaging mode (*includes neonate mode)
  • Programmable NIBP averaging mode (2-5 readings)
  • Nellcor* Oximax SpO2 (*includes neonate mode)
  • Predictive Thermometer (Filac 3000)
  • Connectivity with the EMR – follows the HL7 standard
  • LAN Connectivity as standard
  • Programmable alarms (audible, visible) with 3 priority levels
  • Supports nurse call RJ11 port
  • Internal memory for 5,000 measurements
  • Lithium-ion battery with 11 hours run time (Automatic mode, 15min intervals)
  • Lithium-ion battery with up to 17 hours ON time
  • 2 year warranty

Optional Stand
including basket for storage (cuffs, sensors, cables)

  • Thermal printer (internal)
  • Barcode reader
  • Mobile stand including basket for storage (cuffs, sensors, cables)
  • WiFi
  • NIBP extension tube
  • 2 cuffs (adult & adult large incl. connectors)
  • SpO2 sensor adult
  • SpO2 extension cable
  • Oral temperature probe*
  • Probe cover*
  • (*only if pred. thermometer module is ordered)

Mobile & Precise

The highly flexible, modular design offers many configurations and settings to suit the needs of hospitals, nursing homes and private practices, as well as long-term care settings.


Technical Data


Monitor:
Power Supply: 100 – 240 V AC, 50 ⁄ 60 Hz
Battery:

Lithium-Ion battery, rechargeable, 10.8 V DC, 6,600 mAh, Charging time to a 100%: 6 hours, Operating time approx. 11 hours (new and fully charged battery at 25°:C ambient temperature with connected SpO2, Temp, and NIBP on AUTO mode (15 minutes interval)) Low battery indicator, Charging battery indicator

Dimensions Monitor:

L x H x W: 303 x 230 x 110mm

Weight:

3.6kg including temp module, printer

Dimensions Basket:

L x H x W: 270 x 225 x 200mm

Alarm:

Visible LEDs (Yellow, Red, Blue, Green, Orange)
Audible Speaker
Gives audible alarm, QRS tone
Supports Pitch Tone and multi-level volume
Alarm tones meet the requirement of IEC 60601-1-8.
Alarm Pressure: 45 dB to 85 dB test distance is 1 meter from the tone.

Ports:

1 x AC power inlet
1 x standard RJ45 interfaces.100 BASE-TX, IEEE 802.3
4 x USB ports
1 x Equipotential grounding point
1 x RJ11 connector for nurse call
DC out port 15V ⁄ 1.2 A Clinical-grade NIBP (non-invasive blood pressure)

Clinical-grade NIBP (non-invasive blood pressure)
Measuring method:

automatic oscillometric

Measurement range:

Adult SYS 30 – 270 mmHg, DIA 10 – 220 mmHg, MAP 20 – 235 mmHg
Pediatric SYS 30 – 235 mmHg, DIA 10 – 220 mmHg, MAP 20 – 225 mmHg
Neonate SYS 30-135 mmHg, DIA 10-110 mmHg, MAP 20-125 mmHg

Cuff pressure range:

0 – 280 mmHg

Resolution:

1 mmHg

Pressure accuracy:

Static ±3 mmHg
Clinic ±5 mmHg, standard deviation ² 8 mmHg

Pulse rate range:

40 – 240 bpm

Pulse rate accuracy:

1 bpm

Initial inflation pressure:

Adult 160 mmHg, Pediatric 130 mmHg, Neonate 75 mmHg
Double overpressure protection (hardware and software)
Adult 297 ± 3 mmHg, Pediatric 252 ± 3 mmHg , Neonate 147 ± 3 mmHg

Alarm range:

SYS 0 – 300 mmHg
DIA 0 – 300 mmHg
MAP 0 – 300 mmHg

Nellcor SpO2
Measurement range:

0 – 100%

Resolution:

1%

Accuracy:

70% – 100%: ±2% (adult, pediatric)
70% – 100%: ±3% (neonate)
Unspecified (0% – 69%)

Alarm range:

0 – 100%

Average time:

8 sec, 16 sec

Pulse rate
Measurement range:

20 – 300 bpm

Resolution:

1 bpm

Accuracy:

20 – 250 bpm: ±3 bpm
251 – 300 bpm: unspecified

Predictive thermometer
Oral (Quick Mode)
non-fever temps:

3-5 seconds

fever temps:

8-10 seconds

Oral (Standard Mode):

6-10 seconds

Axillary Mode: 8-12 seconds
Rectal Mode:

10-14 seconds

Direct Mode (all sites):

60-120 seconds

Measurement accuracy:

35.5°C – 42°C

Direct Mode (all sites):

±0.1°C

Standard Prediction Mode (all sites):

±0.1°C

Quick Prediction Mode (oral only):

±0.3°C

Product Codes:
RI.1960-RNBXE:

NIBP (Riester) + SpO2 (Nellcor) + Pred. Temp

RI.1960-RNBPE:

NIBP (Riester) + SpO2 (Nellcor) + Pred. Temp + Printer

RI.13317:

Mobile Stand (basket included)


Click here for a Brochure pdf

email Click here to enquire about the Riester RVS-100 Vital Signs Monitor.


top Return to top of page